Essential Precautions for Restarting Your Air Compressor

After a shutdown or long period of inactivity, restarting an air compressor requires attention to detail and adherence to safe operating procedures. Improper handling may lead to equipment damage or safety risks. Here’s a step-by-step guide on what to check before and during the restart process:

1. Disconnect Power and Check Mechanical Rotation

  • First, switch off the air compressor power supply to ensure all actions are done safely without electricity.
  • Remove the drive shaft guard, then manually rotate the drive coupling to check if the compressor turns freely.
  • If everything moves smoothly, reinstall the guard and prepare for restart.

2. Activate the Cooling Systems

  • For water-cooled compressors, be sure to open the cooling water and blower cooling system valves before starting. This prevents overheating and ensures reliable performance.

3. Start and Gradually Balance Pressure

  • Close the discharge valve and start the compressor.
  • Once the unit is running, slowly open the discharge valve to allow pressure to equalize between the compressor and the compressed air network. Once balanced, the compressor can be brought online.

4. Integrate with Central Control System

  • If your air compressor is linked to a sequencer or system optimizer, confirm that it is properly integrated to avoid conflicts with other units and ensure smooth system performance.

By following these steps, you can ensure a safe and efficient restart process, reduce operational risks, and extend the life of your air compressor system.